Electric control and protection panel of electric pumps installed in pumping systems for sanitation with 2 electric pumps.


Applications

Electric control and protection panel of electric pumps installed in pumping systems for sanitation with 2 electric pumps.

Against lack of water.

Excessive motor consumption (thermal trigger).

Protection of control circuit through circuit breaker.


Operation

After verifying the correct connection of the entire wiring, the motor circuit breakers must be adjusted according to the nominal intensity of the motors.

Check the operation of the pumps by turning the control selector to the Manual () position.

For Automatic operation, set the selector to Automatic (A).

During each actuation of the Alternation Level Buoy signal, alternately switch on Pump 1 or Pump 2.

If during the actuation of the Alternation Level Buoy a performance of the Reinforcement Level Buoy appears, the second available Pump will turn on.

Pump 1 and Pump 2 only switch off when the Minimum Level Buoy signal stops working.

When turning on the Maximum Level Buoy, the two pumps plus the alarm output are switched on. The alarm is canceled when the liquid level is reset.

Safety delay due to delay in starting the electric pumps (adjustable).

Note: The images shown may not correspond completely to the product described.

Additional information

Weight N/A
Dimensions (D x W x H) N/A
Regulação térmica

1,6 – 2,5 A, 2,5 – 4,0 A, 4,0 – 6,3 A, 6,0 – 10,0 A, 9,0 – 14,0 A

Tensão

230V, 400V

Caixa em ABS cinza

260 x 370 x 125 mm with hinge and waterproof polycarbonate cover – IP65

Relé eletrónico modular

Micro controle brand, for alternating command and protection of electric pumps

Contactor e Relé Térmico

Recognized brand

Interruptor

General disconnect

Comutador 3 posições

Manual operation (MAN), automatic OFF (AUT), independently controlled on each electric pump

Ligação para comando remoto do arranque/paragem

By order of the level buoys

Sinalização de alimentação

Indication of the presence of power in the control circuit (White Flag)

Sinalização de eletrobomba

Individual indication of connected pump (Green Flag)

Sinalização disparo térmico

Individual indication of thermal trip (Red Flag)

Sinalização de alarme

Visual and audible alarm signal indication (Red Buzzer)

Acessórios / Outros

8 cable glands for supply and control cables